Analysis of Sewage Treatment Plant at Rai, Sonipat Haryana

Authors

Abhishek Saini, MTech Student, Geeta Singh, Assistant Professor
Environmental Engineering Department, DTU, Delhi, India.

Abstract

Almost 80% of the raw water converted into the wastewater. Wastewater treatment of Municipal waste is the way toward eliminating pollutants from civil wastewater, containing fundamentally family unit sewage including some waste from industries. This research evaluates the performance efficiency of Wastewater Treatment Plant operating on extended aeration process with the average inflow of 7.5 MLD. Fundamentally different wastewater boundaries like pH, TSS, BOD, COD and so forth are inspected at the inlet, outlet and different various destinations of treatment plant. Investigation of quality of water of this plant is a basic as the vast majority of the treated gushing released into Yamuna waterway staying utilized for water system, watering of parks and greens. The consequences of these assessments likewise decide if the emanating released into the water body are under cut-off points given by CPCB. Wastewater tests were gathered at various phases of treatment units and investigated for the significant waste water quality boundaries, for example, BOD, COD, TSS and biodegradability. The normal convergence of boundaries at bay inspecting site pH, BOD, COD, Total Suspended solids, are 7.358, 190.58 mg/l, 588 mg/l and 189.4 mg/l respectively. While the normal convergence of these boundaries, after treatment shows following qualities 7.792, 7.58 mg/l, 32.7 mg/l and 7.8mg/l respectively.